IS810N-INT Series Servo System User Manual (Brief)Chapter 5 Keypad
5.4 Parameter Setting
Parameter setting can be performed on the keypad of a servo drive. For details on the 
parameters, refer to Chapter 8. The following gure shows the keypad operation of switching 
the position control mode to the speed control mode after the power is on.
Figure 5-5 Parameter setting on the keypad
Servo status 
display
 Servo ready
Function code 
group display
Function code 
No. display
Parameter 
value display
Parameter setting 
completed
MODE
MODE
MODE
MODE
ENTER
ENTER
ENTER
●  MODE: Switch the display mode and return to the upper-level menu.
●  UP/DOWN: Increase or decrease the value of the current blinking digit.
●  SHIFT: Shift the blinking digit.
●  ENTER: Save the current setting value or switch to the next-level menu.
After parameter setting is completed, that is, "Done" is displayed, press the MODE key to 
return to the parameter group display (H02-00).