IS810N-INT Series Servo System User Manual (Brief) Chapter 6 Commissioning Software
- 174 -
6.3 Commissioning Cases
6.3.1 Basic Settings of the AM600 Controller for OMET
The following part introduces the communication settings with IS810N by using Inovance
AM600 controller as the master.
Note: To better t for IS810N, it is recommended to use Version 1.10 or a later version of the
AM600 backend.
1) Creating a project
Create an AM600 project. Select
AM600-CPU1608TP
. The interface is shown in the
following gure.
2) Communication setting
Correctly connect the communication cables. To have a normal communication connection,
assign the PC an IP address belonging to the same network segment (192.168.1.xxx) as AM600.
Click
Scan Network
.
Select the found AM600 device. Now the communication connection between PLC and PC is
completed. Then, perform device congurations.
Note: If the AM600 device cannot be found in InoPro, check and turn on the CoDeSys
gateway, and then rescan.