Para.
No.
Address
Name
Value Range
Default
Unit
Change
Page
F2-05 61957
Switchover frequency 2
0.00 Hz to 655.35 Hz 10.00 Hz At once
“
F2-05
”
on page
227
F2-06 61958
VC slip compensation
gain
50% to 200% 100 % At once
“
F2-06
”
on page
227
F2-07 61959
Speed feedback filter
time
0.000s to 0.1000s 004 s At once
“
F2-07
”
on page
227
F2-08 61960
VC deceleration over-
excitation gain
0 to 200 64 - At once
“
F2-08
”
on page
228
F2-09 61961
Torque upper limit
source in speed control
(motoring)
0: Digital setting (F2-10)
1: AI1
2:AI2
3: AI3
4: Reserved
5: Communication
6: MIN (AI1, AI2)
7: MAX (AI1, AI2)
0 - At once
“
F2-09
”
on page
228
F2-10 61962
Torque upper limit
reference in speed
control (motoring)
0.0% to 200.0% 150.0 % At once
“
F2-10
”
on page
229
F2-11 61963
Torque upper limit
source in speed control
(generating)
0: Digital setting (F2-10)
1: AI1
2: AI2
3: AI3
4: Reserved
5: Communication
6: MIN (AI1, AI2)
7: MAX (AI1, AI2)
8: Digital setting (F2-12)
0 - At once
“
F2-11
”
on page
229
F2-12 61964
Torque upper limit
reference in speed
control (generating)
0.0% to 200.0% 150.0 % At once
“
F2-12
”
on page
230
F2-13 61965
Low-speed current loop
Kp adjustment
0.1 to 10.0 1.0 - At once
“
F2-13
”
on page
230
F2-14 61966
Low-speed current loop
Ki adjustment
0.1 to 10.0 1.0 - At once
“
F2-14
”
on page
230
F2-15 61967
High-speed current loop
Kp adjustment
0.1 to 10.0 1.0 - At once
“
F2-15
”
on page
230
List of Drive Unit Parameters