Para.
No.
Address
Name
Value Range
Default
Unit
Change
Page
F4-22 62486
DI active mode setting 1
Ones:
0: Active high
1: Active low
Tens:
0: Active high
1: Active low
Hundreds:
0: Active high
1: Active low
Thousands:
0: Active high
1: Active low
Ten thousands:
0: Active high
1: Active low
0 -
At stop
F4-22
on page
253
F4-23 62487
DI active mode setting 2
Ones:
0: Active high
1: Active low
Tens:
0: Active high
1: Active low
Hundreds:
0: Active high
1: Active low
Thousands:
0: Reserved
Ten thousands:
0: Reserved
0 -
At stop
F4-23
on page
253
F4-25 62489
AI1 hardware source
0: Not selected
1: AI1 of power supply unit
2: AI2 of power supply unit
101: AI1 of extension card 1
102: AI2 of extension card 1
201: AI1 of extension card 2
202: AI2 of extension card 2
0 -
At stop
F4-25
on page
254
F4-27 62491
AI2 hardware source
0: Not selected
1: AI1 of power supply unit
2: AI2 of power supply unit
101: AI1 of extension card 1
102: AI2 of extension card 1
201: AI1 of extension card 2
202: AI2 of extension card 2
0 -
At stop
F4-27
on page
254
F4-29 62493
AI3 hardware source
0: Not selected
1: AI1 of power supply unit
2: AI2 of power supply unit
101: AI1 of extension card 1
102: AI2 of extension card 1
201: AI1 of extension card 2
202: AI2 of extension card 2
0 -
At stop
F4-29
on page
255