F7-02 63234
STOP key function
0: STOP key enabled only in operating
panel control mode
1: STOP key enabled in any operating
mode
0 - At once
“
F7-02
”
on page
275
F7-03 63235
LED display 1 in running
state
Bit00: Running frequency (Hz)
Bit01: Frequency reference (Hz)
Bit02: Bus voltage (V)
Bit03: Output voltage (V)
Bit04: Output current (A)
Bit05: Output power (kW)
Bit06: Output torque (%)
Bit07: DI status
Bit08: DO status
Bit09: AI1 voltage (V)
Bit10: AI2 voltage (V)
Bit11: AI3 voltage (V)
Bit12: Count value
Bit13: Length value
Bit14: Load speed display
Bit15: PID reference
31 - At once
“
F7-03
”
on page
275
F7-04 63236
LED display 2 in running
state
Bit00: PID feedback
Bit01: PLC stage
Bit02: Reserved
Bit03: Running frequency 2 (Hz)
Bit04: Remaining running time
Bit05: Reserved
Bit06: Reserved
Bit07: Reserved
Bit08: Linear speed
Bit09: Current power-on time (min)
Bit10: Current running time (min)
Bit11: Reserved
Bit12: Communication
Bit13: Reserved
Bit14: Main frequency X
Bit15: Auxiliary frequency Y
0 - At once
“
F7-04
”
on page
276
F7-05 63237
LED display in stop state
Bit00: Frequency reference (Hz)
Bit01: Bus voltage (V)
Bit02: DI state
Bit03: DO state
Bit04: AI1 voltage (V)
Bit05: AI2 voltage (V)
Bit06: AI3 voltage (V)
Bit07: Count value
Bit08: Length value
Bit09: PLC stage
Bit10: Load speed
Bit11: PID reference
Bit12: Reserved
51 - At once
“
F7-05
”
on page
276