Parameter Group
-290-
Default:
0.0
Change:
At stop
Value Range:
0.0 min to 6500.0 min
Description
The timing duration is determined by F8-47 and F8-48.
F8-49
AI1 input voltage lower limit
Address:
63537
Min.:
0.00
Unit:
V
Max.: 655.35 Data type: UInt16
Default:
3.10
Change:
At once
Value Range:
0.00 V to 655.35 V
Description
When the AI1 input is higher than F8-50 (AI1 input voltage upper limit) or lower than F8-49 (AI1 input
voltage lower limit), the DO/RO terminal outputs an "AI1 input limit exceeded" active signal to
indicate whether the AI1 input voltage is within the setting range.
F8-50
AI1 input voltage upper limit
Address:
63538
Min.:
0.00
Unit:
V
Max.: 11.00 Data type: UInt16
Default:
6.80
Change:
At once
Value Range:
0.00 V to 11.00 V
Description
When the AI1 input is higher than F8-50 (AI1 input voltage upper limit) or lower than F8-49 (AI1 input
voltage lower limit), the DO/RO terminal outputs an "AI1 input limit exceeded" active signal to
indicate whether the AI1 input voltage is within the setting range.
F8-51
IGBT temperature reach
Address:
63539
Min.:
0
Unit: °C
Max.: 100 Data type: UInt16
Default:
75
Change:
At once
Value Range:
0°C to 100°C
Description
When the IGBT heatsink temperature reaches the value of F8-51, the DO/RO terminal outputs an
active signal.
F8-52
Cooling Fan Control
Address:
63540
Min.:
0
Unit:
-
Max.: 1 Data type: UInt16
Default:
0
Change:
At once
Value Range:
0: Forward running during drive running
1: Forward running continuously
Description