Parameter Group
-306-
The fault protection actions are set by the ones, tens, hundreds, thousands, and ten thousands places
of this parameter.
0: Coast to stop
The AC drive coasts to stop.
2: Special action
The AC drive stops according to the stop command sent by the power supply unit.
5: Disabled
Fault detection is disabled.
F9-51
Fault protection action selection 4
Address:
63795
Min.:
0
Unit:
-
Max.: 55555 Data type: UInt16
Default:
51111
Change:
At stop
Value Range:
Ones: Accumulative running time reach
(E26)
0: Coast to stop
1: Decelerate to stop
4: Warning
5: Disabled
Tens: User-defined fault 1 (E27)
0: Coast to stop
1: Decelerate to stop
4: Warning
5: Disabled
Hundreds: User-defined fault 2 (E28)
0: Coast to stop
1: Decelerate to stop
4: Warning
5: Disabled
Thousands: Accumulative power-on time reach
(E29)
0: Coast to stop
1: Decelerate to stop
4: Warning
5: Disabled
Ten thousands: Load loss (E30)
0: Coast to stop
1: Decelerate to stop
4: Warning
5: Disabled
Description
The fault protection actions are set by the ones, tens, hundreds, thousands, and ten thousands places
of this parameter.
0: Coast to stop
The AC drive coasts to stop.