Table 30: Details of the AC Power Supplies in EX4300 Switches
(Connued)
Details 350 W AC Power
Supply
715 W AC Power
Supply
1100 W AC
Power Supply
1400 W AC
Power Supply
Operang range
Low line: 100–
120 VAC
High line: 200–
240 VAC
Low line: 100–
120 VAC
High line:
200–240 VAC
Low line: 115–
120 VAC
High line:
200–240 VAC
Low line: 100–
140 VAC
High line:
200–240 VAC
NOTE
: In EU countries, Egypt, Nigeria, Saudi Arabia, Serbia, South Korea, and South Africa, you
must ensure that the redundant power supply is installed in the switch chassis.
To prevent electrical injury while installing or removing AC power supplies, carefully follow instrucons
in "Installing an AC Power Supply in an EX4300 Switch" on page 298 and "Removing an AC Power
Supply from an EX4300 Switch" on page 296.
AC Power Supply Airow
Each power supply has its own fan and is cooled by its own internal cooling system.
Each power supply has a label AIR OUT (AFO) or AIR IN (AFI) on the faceplate of the power supply that
indicates the direcon of airow in the power supply.
Table 31 on page 95 lists the AC power supply models and the direcon of airow in them.
Table 31:
Airow Direcon in AC Power Supply Models for EX4300 Switches
Model Label on
Power Supply
Direcon of Airow
JPSU-350-AC-AFO-A AIR OUT
(AFO)
Front-to-back—that is, air intake to cool the chassis is through the
vents on the front panel of the chassis and hot air exhausts through
the vents on the rear panel of the chassis.
95

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4300 Series and is the answer not in the manual?

Juniper EX4300 Series Specifications

General IconGeneral
Product SeriesEX4300 Series
Power ConsumptionVaries by model and configuration
Virtual Chassis TechnologyUp to 10 switches
SoftwareJunos OS
Ports24-port and 48-port models
10GBASE SFP+ PortsUp to 8 ports
40GBASE QSFP+ Ports2
Uplink PortsUp to 4 ports
Jumbo FramesUp to 9216 bytes
Operating Temperature0°C to 45°C
Relative Humidity5% to 90% noncondensing
Input Voltage100 to 240V AC
Power SupplyAC or DC
Power Supply OptionsAC or DC
StackingYes
Layer 2 FeaturesIncludes VLAN, STP, RSTP, MSTP, LACP
Layer 3 FeaturesOSPF, BGP
ManagementCLI, Web GUI, SNMP
Security FeaturesDHCP snooping
QoS8 queues per port, DSCP
Storage Temperature-40°C to 70°C