FPC 3 PLX PCIe Switch TSe OK 51 degrees C / 123 degrees F
FPC 3 PLX PCIe Switch Chi OK 54 degrees C / 129 degrees F
FPC 3 Aloha FPGA 0 TSen OK 51 degrees C / 123 degrees F
FPC 3 Aloha FPGA 0 Chip OK 70 degrees C / 158 degrees F
FPC 3 Aloha FPGA 1 TSen OK 51 degrees C / 123 degrees F
FPC 3 Aloha FPGA 1 Chip OK 75 degrees C / 167 degrees F
FPC 5 Intake Testing
FPC 5 Exhaust A Testing
FPC 5 Exhaust B Testing
Fans Top Rear Fan OK Spinning at intermediate-speed
Bottom Rear Fan OK Spinning at intermediate-speed
Top Middle Fan OK Spinning at intermediate-speed
Bottom Middle Fan OK Spinning at intermediate-speed
Top Front Fan OK Spinning at intermediate-speed
Bottom Front Fan OK Spinning at intermediate-speed
Table 94 on page 336 lists the output elds for the show chassis environment command. The table lists
output elds in the approximate order in which they appear.
Table 94: show chassis environment Output Fields
Field Name Field Descripon
Class Informaon about the category or class of chassis component:
Temp: Temperature of air owing through the chassis in degrees Celsius (°C) and
degrees Fahrenheit (°F)
Fans: Informaon about the status of fans and blowers
Item Informaon about the chassis components:
Flexible PIC Concentrators (FPCs)—that is, the line cards
Control Boards (CBs)
Roung Engines
Power entry modules (PEMs)—that is, the power supplies