ALARMD_MGR_CONNECT
System Log Message function-name evSelectFD: initial pipe create aborted (errno error-code)
Description The alarm process (alarmd) could not open a pipe for interprocess communication (IPC).
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
ALARMD_MULTIPLE_ALARM_BIT_ERROR
System Log Message Multiple alarm bits: 0xalarm-bit
Description The alarm process (alarmd) expected one alarm bit set for an interface alarm when it
received multiple.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
ALARMD_PIDFILE_OPEN
System Log Message Unable to open PID file 'filename': errno error-code
Description The alarm process (alarmd) could not open the file where it stores its process ID (PID).
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Cause The alarm process (alarmd)might have detected that another alarmd process was
running and tried to read the file so that it could use the PID recorded there when
terminating the other process.
ALARMD_PIPE_WRITE_ERROR
System Log Message Pipe write error: error-message
Description The alarm process (alarmd) experienced a fatal error while writing to a pipe.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
63Copyright © 2010, Juniper Networks, Inc.
Chapter 3: ALARMD System Log Messages