BFDD_READ_ERROR
System Log Message Read error on pipe-type pipe: reason (error-message)
Description The Bidirectional Forwarding Detection process (bfdd) could not read the message
available on the indicated type of pipe.
Type Error: An error occurred
Severity info
Facility LOG_DAEMON
Action Contact your technical support representative.
BFDD_TRAP_STATE_DOWN
System Log Message local discriminator: session-id, new state: state
Description The state changed to 'down' or 'admin down' for the indicated Bidirectional Forwarding
Detection process (bfdd) session.
Type Event: This message reports an event, not an error
Severity warning
Facility LOG_DAEMON
BFDD_TRAP_STATE_UP
System Log Message local discriminator: session-id, new state: state
Description The state changed to 'up' for the indicated Bidirectional Forwarding Detection process
(bfdd) session.
Type Event: This message reports an event, not an error
Severity info
Facility LOG_DAEMON
BFDD_WRITE_ERROR
System Log Message function-name: write error on pipe-type pipe (error-message)
Description The Bidirectional Forwarding Detection process (bfdd) could not write a message to the
indicated type of pipe.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
Copyright © 2010, Juniper Networks, Inc.122