CHASSISD_FRU_ONLINE_TIMEOUT
System Log Message function-name: attempt to bring fru-name fru-slot online timed out
Description The indicated component (field-replaceable unit, or FRU) did not come online within the
time that is normally sufficient. After generating this message, the chassis process
(chassisd) tried to bring the FRU online several more times. If all attempts failed, the
chassisd process raised an alarm and left the FRU offline.
Type Event: This message reports an event, not an error
Severity error
Facility LOG_DAEMON
CHASSISD_FRU_STEP_ERROR
System Log Message fru-name fru-slot at step step-number
Description The power-on sequence for the indicated component (field-replaceable unit, or FRU)
failed at the indicated point.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
CHASSISD_FRU_UNRESPONSIVE
System Log Message Error for fru-name fru-slot: error-message; action
Description The chassis process (chassisd) tried to bring the indicated component (field-replaceable
unit, or FRU) online, but the attempt failed in the indicated way. As a result, the chassisd
process performed the indicated action.
Type Event: This message reports an event, not an error
Severity error
Facility LOG_DAEMON
CHASSISD_FRU_UNRESPONSIVE_RETRY
System Log Message Attempt count to power on fru-name fru-slot timed out; restarted it
Description The chassis process (chassisd) tried the indicated number of times to bring the indicated
component (field-replaceable unit, or FRU) online, but the attempts failed. In another
attempt to bring the FRU online, the chassisd process issued the restart command for
the FRU.
Type Event: This message reports an event, not an error
Severity error
Facility LOG_DAEMON
165Copyright © 2010, Juniper Networks, Inc.
Chapter 18: CHASSISD System Log Messages