Action Check the status of the input connections.
CHASSISD_PSU_OVERLOAD
System Log Message Overload condition for power supply pem-slot (status bits: 0xstatus-code);
Description The indicated power supply unit (PSU) reported an output voltage overload condition.
Type Event: This message reports an event, not an error
Severity warning
Facility LOG_DAEMON
Cause There might have been excessive load on the PSU.
CHASSISD_PSU_TEMPERATURE
System Log Message Temperature check bit set for power supply pem-slot; airflow might be inadequate
Description The chassis process (chassisd) detected that the 'temperature check bit' was set in the
status bit mask for the indicated power supply unit (PSU).
Type Event: This message reports an event, not an error
Severity warning
Facility LOG_DAEMON
Cause The PSU might have exceeded its temperature threshold, possibly because the airflow
through it was inadequate.
CHASSISD_PSU_VOLTAGE
System Log Message Power supply pem-slot reports problem; check output voltage
Description The indicated power supply unit (PSU) reported a problem with its output voltage.
Type Event: This message reports an event, not an error
Severity warning
Facility LOG_DAEMON
Cause There might have been excessive load on the PSU.
CHASSISD_RANGE_CHECK
System Log Message function-name: '0xvalue' is invalid value for object-name (out of range)
Description The indicated value was outside the valid range of values for the indicated object.
Type Error: An error occurred
Severity error
197Copyright © 2010, Juniper Networks, Inc.
Chapter 18: CHASSISD System Log Messages