Severity error
Facility LOG_DAEMON
EVENTD_ROTATE_FORK_EXCEEDED
System Log Message Unable to fork: too many child processes
Description The event processing process (eventd) could not create a child process for rotating files
because adding another child would have made the number of children exceed the limit.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
EVENTD_ROTATE_FORK_FAILED
System Log Message Unable to fork: error-message
Description The event processing process (eventd) could not create a child process for rotating files,
for the indicated reason.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
EVENTD_SCRIPT_CHECKSUM_MISMATCH
System Log Message checksum checksum value does not match for script filename
Description Current checksum value of the script does not match with the checksum configured
under [event-options event-script] hierarchy. As a result any event-policy configured
inside the script will not be read
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
EVENTD_SET_PROCESS_PRIV_FAILED
System Log Message Unable to set process privilege level to that of user 'username': error-message
Description In preparation for executing an action defined in a policy, the event processing process
(eventd) tried to change its privilege level to that of the indicated Junos user. The attempt
failed. It made the attempt because the user-name statement is included at one of
several possible levels under the [edit event-options policy <policy-name> then] hierarchy
level.
Type Error: An error occurred
Severity error
261Copyright © 2010, Juniper Networks, Inc.