Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
RDD_IFDEV_GET_FAILURE
System Log Message function-name: rtslib get operation failed for interface device interface-name
(error-message)
Description The redundant interfaces process (rdd) could not get an interface device because an
error occurred during the indicated call to the routing socket library.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
RDD_IFDEV_INCOMPATIBLE_REVERT
System Log Message function-name: did not revert rsp-interface-name back to primary interface
primary-interface-name; PIC is incompatible with secondary
Description The redundant interfaces process (rdd) tried to migrate service processing for the
indicated redundant interface from the secondary interface back to the indicated primary
interface. The attempt failed because the Adaptive Services (AS) Physical Interface
Cards (PICs) that house the primary and secondary interfaces are not compatible.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
RDD_IFDEV_INCOMPATIBLE_SWITCH
System Log Message Unable to switch rsp-interface-name to secondary interface secondary-interface-name;
PIC is incompatible with primary
Description The redundant interfaces process (rdd) tried to migrate service processing for the
indicated redundant interface from the primary interface to the indicated secondary
interface. The attempt failed because the Adaptive Services (AS) Physical Interface
Cards (PICs) that house the primary and secondary interfaces are not compatible.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Copyright © 2010, Juniper Networks, Inc.490