Description The configuration request failed because the indicated configuration object contained
the indicated invalid value.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Modify configuration statement to use a valid value.
RPD_MLD_CFG_SOURCE_OUT_OF_RANGE
System Log Message The combination of source-count count and source-increment ip-address causes some
of the sources out of range.
Description The configuration request failed because the indicated configuration object contained
a source that is out of range.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Modify configuration statement to use a valid value.
RPD_MLD_DYN_CFG_ALREADY_BOUND
System Log Message Dynamic configuration session id client-session-id for interface interface-name is already
bound to interface old-interface-name.
Description The indicated dynamic configuration session id is already bound to another interface.
The dynamic configuration instantiation request was rejected.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Unbind session id from existing interface.
RPD_MLD_DYN_CFG_INVALID_STMT
System Log Message Invalid dynamic configuration statement: configuration-statement
Description The indicated dynamic configuration statement was invalid. The dynamic configuration
instantiation request was rejected.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
535Copyright © 2010, Juniper Networks, Inc.