SNMPD_AUTH_RESTRICTED_ADDRESS
System Log Message function-name: request from address source-address not allowed
Description The indicated function failed because access requests from the indicated source address
are not allowed.
Type Error: An error occurred
Severity notice
Facility ANY
Cause An internal software failure occurred.
Action Contact your technical support representative.
SNMPD_AUTH_WRONG_PDU_TYPE
System Log Message function-name: source-address: unauthorized SNMP PDU type: pdu-type
Description The indicated function failed because the indicated type of protocol data unit (PDU) is
not supported.
Type Error: An error occurred
Severity notice
Facility ANY
Cause An internal software failure occurred.
Action Contact your technical support representative.
SNMPD_BIND_INFO
System Log Message Source address for trap socket was set to bind-address
Description The source address for the indicated type of socket used by the Simple Network
Management Protocol (SNMP) agent process (snmpd) was set to the indicated address.
Type Event: This message reports an event, not an error
Severity info
Facility LOG_DAEMON
Cause An administrator changed the Junos configuration for the process or for an interface.
Cause The online/offline state changed for a PIC. This can also cause the address to become
newly available or unavailable.