Type Error: An error occurred
Severity warning
Facility LOG_DAEMON
Cause The packet was corrupted in transit between the neighboring switch and this switch, or
memory on one of the switches was corrupted.
Action None, unless a large number of these messages appear in the system log file. The
corrupted LSP is purged from the virtual chassis and sent again by the originator.
VCCPD_PROTOCOL_OVERLOAD
System Log Message vccpd database overload
Description The vccpd link-state database is full and no additional memory can be allocated for it.
Type Error: An error occurred
Severity alert
Facility LOG_DAEMON
Cause No additional memory is available for storing vccpd link-state information. Either system
resources are exhausted or a software error occurred (such as a memory leak).
Action Perform one or more of the following actions: (1) Check for unusually high memory usage
by vccpd, (2) Add more memory to the switch.
VCCPD_SYSTEM
System Log Message reason: error-message
Description A system call made by this process failed.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Cause It is possible that the kernel lacked the resources to fulfill the request.
661Copyright © 2010, Juniper Networks, Inc.
Chapter 90: VCCPD System Log Messages