EasyManua.ls Logo

KAESER M27 - Switching off the Generator; Operating the Battery Isolating Switch; Fig. 36 Battery Isolating Switch

KAESER M27
294 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8.5.4 Switching off the generator
Precondition The electric consumers are switched off.
The plugs are removed.
1.
Thermal overload of the turbo generator.
Stopping the machine abruptly after the generator has been in operation for some time can
cause heat damage to the generator.
Allow the motor to run for about 2 minutes in idle before shutting down to allow the genera‐
tor to cool down.
2. Turn the «generator main switch» to the "0" position.
The motor runs in IDLE and the generator can cool down.
After running about 2 minutes in IDLE, the generator has cooled down sufficiently for the en‐
gine to be stopped.
8.6 Option oa
Operating the battery isolating switch
Danger of short circuit!
Damage to the machine electrical system is possible.
Use the «Battery isolating switch» only when the machine is switched off.
Do not use the «Battery isolating switch» as a main or emergency switch!
Fig. 36 Battery isolating switch
1 «Battery isolating switch»
I – On
0 – Off
Raise the cover.
8 Operation
8.6 Operating the battery isolating switch
No.: 9_9548 05 USE
Operator Manual Screw Compressor
M27
91

Table of Contents

Related product manuals