Voltage [V] 400V, 3-phase 230V, 1-phase
Type Brushless synchronous internal pole generator
Control Electronically regulated with control electronics
Enclosure protection IP 54
Tab. 43 Generator data, 400V
Reduced compressed air delivery in generator mode
Voltage [V] 400V, 3-phase 230V, 1-phase
Maximum working pres‐
sure [psig]
100 100
SIGMA airend 11-G 11-G
Reduced delivery [cfm]
Without decrease in pow‐
er output
67 67
Zero delivery [cfm]
With decrease in power
output
0 0
Tab. 44 Compressed air delivery in generator mode
Connections
Voltage [V] 400V, 3-phase 230V, 1-phase
Power sockets Number Number
16 A; 400 V/3~/N/PE 1
16 A; 230 V/1~/N/PE 2
Tab. 45 Connection sockets
Circuit breaker
Voltage [V] 400V, 3-phase 230V, 1-phase
Safety cut-out [A] Number Number
16 1 1
Tab. 46 Circuit breaker
Maximum power loading by consumers
Resistive consumers include lamps and heaters, for example.
Electric motors and transformers are inductive consumers.
Nominal rating conditions
Ambient temperature: 77°F
Max. height above sea level at the place of use: 3000 ft
2 Technical Data
2.7 Options
No.: 9_9548 05 USE
Operator Manual Screw Compressor