Condensate formation in compressed air receivers
Compressed air stored in a containers will cool down. The compressed air precipitates moisture
that collects at the container's bottom. Corrosion may damage the container.
➤
Regularly drain the condensate.
Further information Details of authorized personnel are found in chapter 3.4.2.
Details of dangers and their avoidance are found in chapter 3.5.
8.2 Starting and stopping
Precondition No personnel are working on the machine
Serious damage to engine from cold starting sprays.
Cold-start assists, such as ether or other sprays, can cause severe engine damage.
➤ Do not use cold start sprays.
Fig. 31 Starting instruments
1 «Controller On» switch
2 Instrument panel
3 Operating hours counter
4 Temperature gauge switch
5 «Starter switch »:
0 STOP / OFF
I ON
II Preheating
III START
6
Charging indicating light
,
Group alarm
lamp
7
Compressed air outlet pressure gauge
Notes concerning snow and ice
Considerable snow or ice may build up on the machine under low temperature conditions.
➤
Remove any snow and ice from the machine before operating.
8 Operation
8.2 Starting and stopping
84
Operator Manual Screw Compressor
M27 No.: 9_9548 05 USE