When working on the drive system
Touching rotating, very hot or electrically-live components can result in serious injury.
Shut down the machine before opening any doors/canopy.
Disconnect the negative terminals on the batteries.
Ensure that the machine is cooled down.
Further information Details of authorized personnel are found in chapter 3.4.2.
Details of dangers and their avoidance are found in chapter 3.5.
10.2 Maintenance schedules
10.2.1 Logging maintenance work
The maintenance intervals given are recommended for KAESER original components with
average operating conditions.
In adverse conditions, perform maintenance work at shorter intervals.
Adverse conditions are, e.g.:
high temperatures
a lot of dust
frequent use
Adjust the maintenance intervals with regard to local installation and operating condi‐
tions.
Logging all maintenance work.
This enables the frequency of individual maintenance tasks and deviations from our recom‐
mendations to be determined.
Further information A list is given in chapter 10.9.
10.2.2 Maintenance tasks after commissioning
The table below lists maintenance tasks required after commissioning (initial startup).
Carry out maintenance tasks according to the following schedule.
Component:
Task
After the first
50 h
After the first
half year
(250 hours)
See chapter
Note
Engine:
Change oil. X 10.3.4 Engine
SM
Change the oil filter. X Engine
SM
h = operating hours; Engine SM = engine manufacturer's service manual; SW = specialized work‐
shop
10 Maintenance
10.2 Maintenance schedules
No.: 9_9548 05 USE
Operator Manual Screw Compressor
M27
103

Table of Contents