Making operational:
1.
Reconnect the negative battery terminal.
2. Close the canopy.
Dispose of old parts and contaminated materials according to environmental regulations.
Starting the machine and performing a test run:
1.
Switch the machine on and run it in IDLE mode for approximately 5 minutes.
2. Shut down the machine.
3. Wait until the machine has automatically vented.
Pressure gauge reads 0 psig!
4. Open the outlet valves.
5. Open the canopy.
6. Carry out a visual check for leaks.
7. Shut down the machine.
8. Close the canopy.
10.4.6 Changing the oil separator cartridge
The oil separator cartridge cannot be cleaned.
The life of the oil separator cartridge is influenced by:
■
contamination in the air drawn into the compressor,
■ and adhering to the changing intervals for:
─ Cooling oil
─ Oil filter
─ Air filter
Material Spares
Cleaning cloth
Wrench
Precondition The machine is shut down.
The machine is fully vented, the pressure gauge reads 0 psig.
Machine is cooled down.
All compressed air consumers are disconnected and the air outlet valves are open.
The negative cable to the battery is disconnected.
➤ Open the canopy.
10 Maintenance
10.4 Compressor Maintenance
136
Operator Manual Screw Compressor
M27
No.: 9_9548 05 USE