7.2.2 Special measures for recommissioning after storage
Carry out the following before every start-up after long period of storage:
Storage
period longer
than:
Remedy
5 months Remove the desiccant from the openings in the air intake filters of the engine
and compressor.
Check the air and oil filters.
Drain the preserving oil from the separator tank.
Fill with cooling oil.
Drain the preserving oil from the engine.
Fill with engine oil.
Check the engine coolant
Check the battery charge.
Re-connect the battery (batteries).
Check all fuel lines, engine oil lines and compressor cooling oil lines for leaks,
loose connections, wear and damage.
Clean the bodywork with a grease and dirt dissolving agent.
Check the tire pressures.
36 months Have the overall technical condition checked by an authorized KAESER service
representative.
Tab. 64 Measures for recommissioning the compressor after a long period of storage
7.3 Checking installation and operating conditions
Check and confirm all the items in the checklist before starting the machine.
Task See chapter Confirmed?
Are the operators completely familiar with safety regulations?
Have all the positioning conditions been fulfilled? 5
Is there sufficient cooling oil in the separator tank? 10.4.1
Is there sufficient oil in the engine? 10.3.4
Is the maintenance indicator on the air intake filters (engine and
compressor) OK?
10.3.2,
10.4.7
Is there sufficient coolant in the coolant expansion tank? 10.3.1
Is there sufficient fuel in the fuel tank?
Is there sufficient tool oil in the tool lubricator? (Option ea, ec) 10.8.1
Is there enough antifreeze in the frost protector? (Option ba) 10.8.3
Are the access doors closed and all body panels in place?
Are the tire pressures OK?
Tab. 65 Installation conditions checklist
7 Initial Start-up
7.3 Checking installation and operating conditions
76
Operator Manual Screw Compressor
M27 No.: 9_9548 05 USE