8.2.4 The machine is running under load
Precondition The airend discharge temperature must be at least 86 °F
1. Connect the consumer to the compressed air outlet valves.
2.
Open the compressed air outlet valves.
8.2.5 Shutting down the machine
1. Close the «compressed air outlet valves» on the air distributor.
The engine runs in IDLE.
2. Turn the «starter switch» to “0 position.
The engine turns off.
Shutting down the machine
1. Raise the cover.
2. Turn the «controller ON» switch to “0” position.
3. Close the canopy.
Lock the canopy if necessary.
8.3 Option ea
Operating the tool lubricator
Precondition The machine is shut down.
Tool lubricator filled with oil
8 Operation
8.3 Operating the tool lubricator