5. Install the charging power unit
to the steel frame using four M12
bolts.
At first, tighten the bolts only
loosely. Once all the bolts are in
place, tighten them completely.
NOTE
If the charging power unit
does not fit correctly onto the
steel base, you may need to
go back and readjust the steel
base.
6. Finalize the installation of the charging power unit. For instructions,
see 5.1.9: Installing the charging power unit.
5.1.2.2. Installing the steel base (double)
WARNING
Do not go under the unit when it is lifted.
CAUTION
Use all lifting lugs of the unit when you lift it. Minimum angle of slings 60 degrees.
CAUTION
High center of gravity. Make sure that the cabinet does not fall over.
NOTICE
One cabinet with four power modules weighs approximately 400 kg. Use appropriate
lifting equipment operated by qualified professionals.
NOTICE
Make sure that the installation surface is solid and as level as possible.
NOTICE
Make sure that the door of the unit has space to open when the unit is in position.
NOTE
Note the cable routes and open the necessary knock-out holes of the steel base. Use
cable bushings or file the sharp metal edges of the knock-out holes to protect the
cables from damages.