If “%” is used in a string of text when “FleetSync ID” is configured in Message Type, “%” appears replaced with the Fleet
(Own) and ID (Own) of the system configured in Preset System Number.
Example:
Fleet (Own) = 110
ID (Own) = 1911
Power-on Text = “NYPD %%%-%%%%”
Note
Pressing a key while the Power-on Text appears causes the Power-on Text to disappear.
Configuration using KPG-D1/ D1N
0
Configuring Power-on Text
and Message Type (
Transceiver
Settings > Optional Features > Optional Features
1 > Power-on)
0
Configuring Preset System Number ( Transceiver Settings > Optional Features > Optional Features 1 > Power-on)
Sub-LCD Display
Sub-LCD Display is
the function to display the transceiver information on the display while the transceiver is in the normal
state.
Table 5-5 Sub-LCD Display
Configuration Description
None Nothing appears.
Zone Number The zone number appears.
Channel Number The channel number appears.
OST List Number The OST List number appears.
Site Number
The site number of the fixed site appears while Site Lock is enabled.
The site number of the current site appears if the transceiver has acquired a control
channel
while Site Lock is disabled. The site number does not appear if the transceiver
does not acquire a control channel while Site Lock is disabled.
Note
Site Number can be used only in an NXDN Trunking system.
Configuration using KPG-D1/ D1N
Configuring Sub-LCD Display (
Transceiver Settings > Optional Features > Optional Features 1 > Display)
5 INDICATION AND DISPLAY
5.11 Display Functions of the Display
Common FUNC (K, F)/Ver 2.20 102
CONTENTS INDEX