G-23
MX5100, WSM
G GENERAL
[4] CHECK POINTS OF EVERY 100 HOURS
Checking Battery Condition
Do not use or charge the refillable type battery if the fluid
level is below the LOWER (lower limit level) mark.
Otherwise, the battery component parts may prematurely
deteriorate, which may shorten the battery’s service life or
cause an explosion. Check the fluid level regularly and add
distilled water as required so that the fluid level is between
the UPPER and LOWER levels.
CAUTION
Never remove the vent caps while the engine is running.
Keep electrolyte away from eyes, hands and clothes. If you
are spattered with it, wash it away completely with water
immediately and get medical attention.
Wear eye protection and rubber gloves when working
around the battery.
The factory-installed battery is of non-refillable type. If the
indicator turns white, do not change the battery but replace it with
new one.
1. Mishandling the battery shortens the service life and adds to
maintenance costs.
2. The original battery is maintenance free, but need some
servicing.
If the battery is weak, the engine will be difficult to start and the
lights will be dim. It is important check the battery periodically.
How to read the indicator
Check the battery condition by reading the indicator.
W10790200
State of indicator display
Green
Specific gravity of electrolyte and quality of
electrolyte are both in good condition.
Black Needs charging battery
White Needs replacing battery
(1) Battery (2) Indicator