9-S12
MX5100, WSM
ELECTRICAL SYSTEM
(4) Operator Presence Control
■ Preparation before checking
1. Sit on operator's seat.
2. Set the parking brake.
3. Shift the main gear shift lever and the synchro-shuttle shift lever to “NEUTRAL” position.
4. Shift the PTO lever (PTO clutch control lever) to “OFF” position.
5. Fully depress the clutch pedal and start the engine.
6. Check the OPC system by following four steps listed in the table below.
IMPORTANT■
• Main gear shift lever is set to “NEUTRAL” position.
Checking Procedure
Step PTO lever
Synchro-shuttle shift
lever
Operator
OPC system is
“NORMAL” if
1
“OFF” position
(Switch : ON)
“Forward” or
“Reverse”
(Switch : OFF)
Gets up from the seat
(Seat switch : OFF)
Engine stops
2
“ON” position
(Switch : OFF)
“NEUTRAL”
(Switch : ON)
Gets up from the seat
(Seat switch : OFF)
Engine stops
3
“OFF” position
(Switch : ON)
“NEUTRAL”
(Switch : ON)
Gets up from the seat
(Seat switch : OFF)
Engine does not stop
4
“OFF” position
(Switch : ON)
“NEUTRAL”
(Switch : ON)
Gets off the tractor,
tilts the seat forward,
and then place PTO
lever in ON position
(Seat switch : ON)
Engine does not stop

Table of Contents