9-S11
MX5100, WSM
ELECTRICAL SYSTEM
(3) Safety Switch
Safety Switch Continuity
1. Disconnect the connectors (3) from the PTO lever safety
switches (2).
2. Disconnect the connectors from the shuttle lever neutral switches
(5).
3. Connect the circuit tester to each safety switch's terminals.
4. Measure the resistance between terminals.
5. If any safety switch is defective, replace it.
W1066307
Resistance (Across PTO
lever safety switch
terminals)
When switch is
pushed
0 Ω
When switch is
released
Infinity
Resistance (Across
shuttle lever neutral
switch terminals)
When switch is
pushed
0 Ω
When switch is
released
Infinity
(1) PTO Lever
(2) PTO Lever Safety Switches
(3) Connector (for PTO Lever Safety
Switch)
(4) Synchro-Shuttle Shift Lever
(5) Shuttle Lever Neutral Switches
(6) Connector (for Shuttle Lever Neutral
Switch)
A : PTO Lever “ON” Position
B : PTO Lever “OFF” Position
C : Synchro-Shuttle Shift Lever
“Reverse” Position
D : Synchro-Shuttle Shift Lever
“Neutral” Position
E : Synchro-Shuttle Shift Lever
“Forward” Position