G-40
MX5100, WSM
G GENERAL
Flushing Cooling System and Changing Coolant (Continued)
5. Adding the LLC
(1) Add only water if the mixture reduces in amount by
evaporation.
(2) If there is a mixture leak, add the LLC of the same
manufacturer and type in the same mixture percentage.
*Never add any long-life coolant of different manufacturer.
(Different brands may have different additive components, and
the engine may fail to perform as specified.)
6. When the LLC is mixed, do not employ any radiator cleaning
agent. The LLC contains anticorrosive agent. If mixed with the
cleaning agent, sludge may build up, adversely affecting the
engine parts.
7. Kubota’s genuine ling-life coolant has a service life of 2 years. Be
sure to change the coolant every 2 years.
NOTE
The above date represent industry standards that
necessitate a minimum glycol content in the concentrates
anti-freeze.
When the coolant level drops due to evaporation, add water
only to keep the antifreeze mixing ratio less than 50 %. In
case of leakage, add antifreeze and water in the specified
mixing ratio before filling in to the radiator.
W10961020
Replacing Fuel Hose
1. Refer to “Checking Fuel Line” shown in page G-27.
W11086610
Replacing Power Steering Hose
1. Refer to “Checking Steering Oil Line” in “CHECK POINTS OF
EVERY 200 HOURS”.
W11092550
Replacing Radiator Hose (Water Pipes)
1. Refer to “Checking Radiator Hose and Hose Clamp” in “CHECK
POINTS OF EVERY 200 HOURS”.
W11092960
Replacing Intake Air Line
1. Refer to “Checking Intake Air Line” in “CHECK POINTS OF
EVERY 200 HOURS”.
W11093370

Table of Contents