G-42
MX5100, WSM
G GENERAL
Replacing Fuse
1. The tractor electrical system is protected from potential damage
by fuses.
A blown fuse indicates that there is an overload or short
somewhere in the electrical system.
2. If any of the fuses should blow, replace with a new one of the
same capacity.
IMPORTANT
Before replacing a blown fuse, determine why the fuse blew
and make any necessary repairs. Failure to follow this
procedure may result in serious damage to the tractor
electrical system. Refer to “TRABLESHOOTING” section of
this manual.
Protected Circuit
W10393150
Replacing Light Bulb
1. Head lights and rear combination lights :
Take the bulb out of the light body and replace with a new one.
2. Other lights :
Detach the lens and replace the bulb.
W10396590
Fuse No. Capacity Protected circuit
(1) 10 A Working Light
(2) 10 A Panel
(3) 5 A Head Light
(4) 5 A Key Stop
(5) 5 A Glow Lamp
(6) 5 A Starter Relay
(7) 15 A Head Lamp Relay (Hi)
(8) 15 A Head Lamp Relay (Lo)
(9) 15 A Hazard
(10) 50 A Key Switch
(11) 50 A Main
(12) 30 A Key Stop
a : Fuse Box
Light Capacity
Head Light 60 W / 55W
Tail Light 8 W
Turn Signal / Hazard Light (Rear) 23 W
Turn Signal / Hazard Light (Rear) 27 W
Instrument Panel Light 1.7 W