EasyManua.ls Logo

Kyocera ECOSYS M3040dn

Kyocera ECOSYS M3040dn
483 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2NM/2NX/2NY/2NZ/2P0/2P6-1
1-3-59
Setting: [Adjust Original] *: This setting is usually unnecessary.
Display Description Setting range Initial setting
Dist1 Sets the adjustment value of a leading
edge.
4.0 to 6.0 5.0
Dist2 Sets the adjustment value of a left edge. 9.0 to 11.0 10.0
Dist3 Sets the adjustment value of a trailing
edge.
265.0 to 267.0 266.0
1. Measure the distance from the leading edge to the top of black belt 1 of the original at A, B and
C.
Measurement procedure
1) Measure the distance from the leading edge to the top of black belt 1 of the original at A (30
mm from the left edge), B (105 mm from the left edge) and C (180 mm from the left edge),
respectively.
2) Apply the following formula for the values obtained: ((A + B + C) / 3)
2. Enter the values solved using the cursor right/left keys or numeric keys in [Dist1].
3. Press the start key. The value is set.
4. Measure the distance from the left edge to the right edge black belt 2 of the original at F.
Measurement procedure
1) Measure the distance from the left edge to the right edge black belt 2 of the original at F (21
mm from the top edge of black belt 1).
5. Enter the values using the cursor right/left keys or numeric keys in [Dist2].
6. Press the start key. The value is set.
7. Measure the distance from the top edge of black belt 1 to the bottom of black belt 3 of the orig-
inal at D and E.
1) Measure the distance from the top edge of black belt 1 to the bottom of black belt 3 of the
original at D (30 mm from the left edge) and E (180 mm from the left edge), respectively.
2) Apply the following formula for the values obtained: (D/2 + E/2)
8. Enter the measured value using the cursor right/left keys or numeric keys in [Dist3].
9. Press the start key. The value is set.
Figure 1-3-16
Original for adjustment
(P/N: 302NM94340)
F
A
B
C
D
E
30mm 105mm 180mm
21mm
Leading edge
Left edge
[Dist1] = (A+B+C)/3
[Dist2] = F
[Dist3] = D/2+E/2
Black belt 1
Blackbelt 2
Black belt 3

Table of Contents

Other manuals for Kyocera ECOSYS M3040dn

Related product manuals