2NM/2NX/2NY/2NZ/2P0/2P6-1
1-5-94
1-5-12 Othes
(1) Detaching and refitting the main driving motor unit
Procedure
1. Remove right middle cover.
(See page 1-5-90)
2. Remove right lower cover.
(See Page 1-5-91)
3. Pull the connector out from the motor
and then release the wires from wire
holder.
4. Remove three screws and then remove
the main driving motor unit.
5. Check or replace the main driving motor
unit and refit all the removed parts.
Figure 1-5-161
Figure 1-5-162
Connectors
Wires
Wire holders
Main drive
motor unit
Screws
(50/60 ppm model)
Connector
Wires
Wire holders
Main drive
motor unit
Screws
(40 ppm model)