EasyManua.ls Logo

LDI DIGISONDE 4D - CHAPTER 4 _ ADVANCED INTERFACE of DCART; Summary of Advanced Features in Dcart; Cross-Channel Equalizing of the Receiver Channels

Default Icon
321 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LDI Intellectual Property.
Not for secondary distribution or replication, in part or entirety.
DIGISONDE-4D
SYSTEM MANUAL
VERSION 1.2.11
3-68 SECTION 3 - OPERATING INSTRUCTIONS
CHAPTER 4
ADVANCED INTERFACE OF DCART
SUMMARY OF ADVANCED FEATURES IN DCART
3:128. The following categories of DCART operations are considered to be available to advanced users:
Programming and analysis of Cross-Channel Equalizing (CCEQ) data,
Programming and analysis of Tracking Filter Calibration data,
Direct hardware commanding,
Global redefinition of data production options,
Commanding of DESC into Diagnostic and Standby state for manual uploads, and
Manual production of SSTs.
3:129. Use Options General menu of DCART to switch it into Advanced interface mode, in which DCART
windows shows additional controls and content tabs (see Figure 3-49).
Cross-Channel Equalizing of the Receiver Channels
3:130. The CCEQ operation switches Digisonde-4D into internal loopback configuration, in which antenna
switch is commanded to use loopback signal from Transmitter Card instead of receiving antennas
(Figure 3-49).