LDI Intellectual Property.
Not for secondary distribution or replication, in part or entirety.
DIGISONDE-4D
SYSTEM MANUAL
VERSION 1.2.11
SECTION 5 - SYSTEM SOFTWARE – ANNEX A 5-33
Databin format. It is defined only for Generic format, in
which case the databin format number is:
a). For Raw or Time Domain data type
0 - uncompressed
1 - compressed
b). For Doppler data type
0 - uncompressed
1 - compressed
c) For Ionogram data type
0 - all-antennas uncompressed
1 - all-antennas compressed
2 - antenna-convolved uncompressed
3 - antenna-convolved compressed
4 - antenna-convolved very compressed
Lower Frequency Limit
This field’s used when Frequency Stepping Law is Linear or
Logarithmic
Upper Frequency Limit
This field’s used when Frequency Stepping Law is Linear or
Logarithmic
Fixed Frequency
This field’s used when Frequency Stepping Law is Fixed
Frequency
Fixed Frequency Repeats
This field’s used when Frequency Stepping Law is Fixed
Frequency
Frequency Stepping Law
0 = Linear
1 = Logarithmic
2 = Fixed Frequency (Lower Frequency Limit value is used)
3 = Flex List (user-defined list of operating frequencies)
Flex List Size
Size of Flex List (number of user-defined frequencies).
This field’s used when Frequency Stepping Law is Flex List.
Coarse Frequency Step
This field’s used when Frequency Stepping Law is Linear or
Logarithmic
Fine step multiplexing
0 = no multiplexing
1 = multiplexing
Multiple frequency operation (constant, set to single fre-
quency mode)
0 = single frequency mode
1 = dual frequency mode
2 = quadruple frequency mode
Waveform
1 = 16-chip complimentary code
2 = 67 s short pulse
Interpulse phase switching (constant, set to disabled)
0 = disabled
1 = enabled
Transmitter mode
0 = off
1 = on