How to commission the technology applicaon:
1. Enter the gearbox rao in the kinemacs dialogue.
a)
In the par
ameter Gearbox factor - numerator, enter the gearbox rao = 12. 40x500A:
033
b)
In the parameter Gearbox factor - denominator enter the gearbox rao = 1. 40x500A:
034
The feed constant has no inuence on the movement in this technology applicaon, but
only denes the unit of the general speed displays. The parameter Feed constant has the
basic seng 360.0000[°]. 40x500A:032
2.
Select the base sengs in the technology applicaon dialogue.
a)
Set the Winding direcon with line velocity > 0 = false. 40x5051:011
The winder will now operate as a rewinder.
b)
Set the Line velocity reference = 1000.0000 [mm/s]. 40x5051:012
The reference speed corresponds to the maximum line speed.
c)
Use Line velocity source = 3 to select the source of the line speed. 40x5020:020
d)
Set the Evaluaon line velocity - numerator = 2387610. 40x5051:007
e)
Se
t the Evaluaon line velocity - denominator = 360000. 40x5051:008
3. Switch to the "Calculate diameter" dialogue.
a)
Enter Min. reel diameter = 76.0000 [mm]. 40x5051:016
b)
Enter Max. reel diameter = 1250.0000 [mm]. 40x5051:017
c)
Enter Start diameter = 76.0000 [mm]. 40x5051:066
4. Switch to the "Manual line jogging" dialogue.
The winder can only be tested in manual operaon. This must be done without
an
y material inside the machine.
a) To load the diameter = 76 [mm], set the value = TRUE in bit 22 of the parameter Con-
tr
ol word. 0x5050:010
b) To move the line in a posive direcon, set the value = TRUE in bit 5 of the parameter
Control word. 0x5050:010
c) To move the line in a negave direcon, set the value = TRUE in bit 6 of the parameter
Control word. 0x5050:010
The direcon of rotaon of the winding sha is set. If the sha rotates in the opposite
direcon, invert the motor mounng posion.
d)
Adapt the direcon of rotaon in the parameter Motor mounng direcon. 40x500A:
035
To do so, refer to the table "Overview of the winding sha’s direcon of rotaon
depending on the bit sengs" at the end of the chapter.
5. Scale the signal of the actual posion of the dancer.
The reference values are congured using the teach funcon.
a) Switch to the "Dancer posion evaluaon" dialogue.
b)
In the parameter Set dancer posion (input value), select = AnalogIn [1].
40x5050:023
c) In the parameter Dancer limit posion source, select = Teached values [TRUE].
40x5052:173
d) In the parameter Stored material length in dancer, enter = 1600.0000 [mm].
40x5052:200
The length is required for the inial diameter
idencaon when liing the dancer.
e) Move the dancer manually to the lower posion.
Conguring the "Winder Dancer" TA
Commissioning
93