Printer hardware error messages(100199.99)
User attendance messages
Error code Description Action
111.30 Printhead ID error See “Printhead ID service check” on page 106.
111.31 Printhead no first HSYNC error See “Printhead service check” on page 106.
111.32 Printhead loss of HSYNC error See “Printhead service check” on page 106.
111.33 Printhead loss of HSYNC during servo See “Printhead service check” on page 106.
111.34 Printhead mirror motor loss of lock See “Printhead service check” on page 106.
111.35 Printhead mirror motor initial lock See “Printhead service check” on page 106.
111.36 Printhead mirror motor stabilization error See “Printhead service check” on page 106.
111.37 Page reached input sensor but the mirror
motor was not locked
See “Printhead service check” on page 106.
111.38 Page reached input sensor but the
printhead startup was not complete
See “Printhead service check” on page 106.
111.90 Printhead video cable not plugged in See “Printhead service check” on page 106.
120.10 Fuser drive Motor Halls detection error See “Fuser drive motor service check” on page 107.
120.20 Fuser drive Motor took too long to stop See “Fuser drive motor service check” on page 107.
120.30 Fuser drive Motor Unable To Lock (before
motor ID)
See “Fuser drive motor service check” on page 107.
120.40 Fuser drive motor overspeed error See “Fuser drive motor service check” on page 107.
120.60 Fuser drive motor unable to lock (after
motor ID)
See “Fuser drive motor service check” on page 107.
120.70 Fuser drive motor out of lock See “Fuser drive motor service check” on page 107.
120.80 Fuser drive motor excessive PWM / over
temperature
See “Fuser drive motor service check” on page 107.
121.07 Fuser has been on for more than allowed
after a gap blowout, and the temperature
is still too cold
See “Fuser service check” on page 107.
121.08 Fuser was under temperature when page
was in fuser
See “Fuser service check” on page 107.
121.20 Fuser undertemp during steady state
control
See “Fuser service check” on page 107.
121.22 Fuser did not warm enough to start line
voltage detection
See “Fuser service check” on page 107.
121.23 Fuser took too long to heat to line
detection temperature
See “Fuser service check” on page 107.
121.24 Fuser never reached fuser detection
temperature
See “Fuser service check” on page 107.