4 Crimp both connector pins (A) using pliers to make them fit through the pin holes. Push the connector off its slot.
5 Route the interface cable off the drawer, and remove.
Note: Pay attention to the original routing of the cable.
Sensor (HCIT media low) with flag removal
1 Remove the HCIT. See “HCIT removal” on page 423.
2 Remove the drawer assembly rear cover. See “HCIT drawer assembly rear cover removal” on page 428.
3 Remove the drawer assembly left cover. See “HCIT drawer assembly left cover removal” on page 429.
4 Release the latches (A) securing the sensor to the drawer.
4063