Sensor Tests
Use this test to determine if the input tray sensors are working correctly.
1 From the Diagnostics menu, navigate to:
INPUT TRAY TESTS > Sensor Tests
2 Select the input source. All installed sources appear.
Not all sensors appear for all trays. The following table indicates which tray sensors are available for each input
source:
Input source Empty
(Input tray empty
sensor)
Low
(Input tray paper low
sensor)
Pass through sensor
Tray 1
Tray 2
Tray 4
Tray 5
Multipurpose feeder
Envelope feeder
3 Manually actuate each sensor. The tray empty sensor can be actuated by hand; however, a sheet of paper can be
used to cover the pass through sensor.
4 Press X to exit the test.
OUTPUT BIN TESTS
Feed Tests
This test verifies that media can be fed to a specific output bin. No information is printed on the media.
To run the feed tests:
1 From the Diagnostics menu, navigate to:
OUTPUT BIN TESTS > Feed Tests
2 Select the output bin into which you want the paper to exit. All installed output bins appear.
3 Select one of the following:
SingleFeeds a single page
Continuous—Continuously feeds pages until X is pressed
Feed To All Bins
This test verifies that media can be fed to the standard bin or any installed output options. No information is printed
on the media.