EasyManua.ls Logo

Lexmark MS81x - Page 116

Lexmark MS81x
659 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Error code Description Action
959.30 Smart chip library flagged an invalid argument(s) Replace the controller board. Go to “Controller
board removal” on page 349.
959.31 Smart chip library flagged an invalid device address
959.32 Failure to initialize physical interface
959.33 Unknown/unexpected Error
959.34 System smart chip Bus Busy Error
959.35 Transmission Error
959.36 Smart chip command is invalid due to unlocked device
status
959.37 Smart chip command is invalid due to locked device
status
959.38 Incremental counter id(s) are invalid
959.39 Invalid NV address
959.40 Invalid smart chip command Replace the controller board. Go to “Controller
board removal” on page 349.
960.xx RAM Memory Error—RAM soldered on the card is bad
961.xx RAM Memory Error—optional DRAM is bad Replace the bad memory card.
964.xx Download Emulation Cyclic Redundancy Check (CRC)
Error—checksum failure detected in the emulation
header or emulation file.
1 Disable the Download Emulation.
2 Program the download emulation into the
firmware card again.
3 If the above steps do not resolve the problem,
then replace the firmware card and download
the emulation again.
975.xx Network Error—unrecognizable network port Call the next level of support.
976.xx Network Error—unrecoverable software error in
network port
978.xx Network Error—bad checksum while programming
network port
979.xx Network Error—flash parts failed while programming
network port
4063
Diagnostic information
116

Table of Contents