G
8-8
No.
Comm.No.
Function Display
Name
Setting Range
Initial Value
Shift in
Operation
Control Mod
e
V/
F
SL
VC
SLT
VCT
24 0h1318 Freq Limit
frequency limit
0N
o
0:No
X O O O X X
1Yes
2
5
Note10)
0h1319 Freq Limit Lo
frequency lower limit 0 ~ upper limit [Hz]
0.50
O O O O X X
26 0h131A Freq Limit Hi
frequency upper limit 0.5 ~ max. freq. [Hz]
60.00
X O O O X X
27 0h131B Jump Freq
frequency jump
0 No
0:No
X O O O X X
1Yes
2
8
Note 11)
0h131C Jump Lo 1
jump freq. lower limit 1
0
~
jum
p
freq.
upper limi
t
1[Hz]
10.00
O O O O X X
29 0h131D Jump Hi 1
jump freq. upper limit 1
Jump freq. lower limi
t
1
~
max. freq. [Hz]
15.00
O O O O X X
30 0h131E Jump Lo 2
jump freq. lower limit 2
0
~
jum
p
freq.
upper limi
t
2
[Hz]
20.00
O O O O X X
31 0h131F Jump Hi 2
jump freq. upper limit 2
Jump freq. lower limi
t
2
~
max. freq. [Hz]
25.00
O O O O X X
32 0h1320 Jump Lo 3
jump freq. lower limit 3
0
~
jum
p
freq.
upper limi
t
3[Hz]
30.00
O O O O X X
33 0h1321 Jump Hi 3
jump freq. upper limit 3
Jump freq. lower limi
t
3
~
max. freq. [Hz]
35.00
O O O O X X
41
Note12)
0h1329 BR Rls Curr
brake open current 0 ~ 180.0 [%]
50.0
O O O O X X
42 0h132A BR Rls Dly
brake open delay time 0 ~ 10.00 [s]
1.00
X O O O X X
44 0h132C BR Rls Fwd Fr
brake open
forward frequency
0 ~ max. freq. [Hz]
1.00
X O O O X X
45 0h132D BR Rls Rev Fr
brake open
reverse frequency
1.00
X O O O X X
46 0h132E BR Eng Dly
brake close delay time 0 ~ 10 [s]
1.00
X O O O X X
47 0h132F BR Eng Fr
brake close frequency 0 ~ max. freq. [Hz]
2.00
X O O O X X
50 0h1332 E-Save Mode
energy saving operation
0 None
0: None
X O O X X X
1 Manual
2Aut
o
51
Note13)
0h1333 Energy Save
energy saving amount 0 ~ 30 [%]
0
O O O O X X
60 0h133C
Xcel Change
Fr
Acc/Dec time exchange
frequency
0 ~ max. freq. [Hz]
0.00
X O O O X X
* The grey code refers to hidden code, emerging only in case of setting of the code.
Note 8)
ADV-12 is displayed only when ADV-07 “Stop Mode” is set as “Dc-Start”.
Note 9)
ADV-14~17 is displayed only when ADV-08 “Stop Mode” is set as “DC-Brake”.
Note 10)
ADV-25~26 is displayed only when ADV-24 (Freq Limit) is set as “Freq Limit”.
Note 11)
ADV-28~33 is displayed only when ADV-27 (Jump Freq) is set as “Yes”.
Note 12)
ADV-41~47 is displayed only when a code of OUT-31~33 is set as “BR Control”.
Note 13)
ADV-51 is displayed only when ADV-50 (E-Save Mode) is set as values other than “None”.

Table of Contents

Other manuals for LSIS SV-iS7 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LSIS SV-iS7 series and is the answer not in the manual?

LSIS SV-iS7 series Specifications

General IconGeneral
BrandLSIS
ModelSV-iS7 series
CategoryInverter
LanguageEnglish

Related product manuals