Countermeasures
136
Home return ACC time setting error
• Home return ACC time > 10,000
Stop Re-adjust home return ACC time lower than 10,000
137
Home return DEC time setting error
• Home return DEC time > 10,000
Stop R-adjust home return Dec time lower than 10,000.
151 Operation speed ‘0’ setting error of operation data Stop Set operation speed over ‘0’.
152
Operation speed of operation data exceeding the max
speed
Stop Re-adjust to be max speed ≥ operation speed.
153
Operation speed of operation data set lower than bias
speed.
Stop Re-adjust to be operation speed ≥ bias speed.
154 Exceeding dwell time setting range of operation data Stop Set dwell time lower than 50000.
155
Exceeding end/continuous/sequential setting range of
operation data
Stop
Re-set operation pattern of operation data as one of 0:end
1:continuous or 2:sequential
201 Home return command is unavailable during operation Stop
Check whether command axis was not operating at the time o
home return command.
202
Home return command is unavailable in case of ‘no output’
status.
Stop
Check whether command axis was not in ‘no output’ status at th
time of home return command.
211
Floating origin setting command is unavailable during
operation.
Stop
Check whether command axis was not operating at the time o
floating origin setting command.
221 Direct start command is unavailable during operation. Stop
Check whether command axis was not operating at the time of
direct start command