NTP-003
: Acceptance 363-206-305
Page 4 of 4 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED. . . . .FOR DETAILS, GO TO
6.
NOTE:
If the shelf has not been equipped for the required low-speed
protection mode, refer trouble to the organization that
installed the shelf or use procedures of
NTP-011
to install
the correct protection mode assembly.
Use rtrv-eqpt command to verify shelf is equipped for
low-speed protection mode required (
Low speed protection
mode: 1X1
or
1X7
). Verify proper protection mode designation
strip label has been placed on the front of the shelf on the middle
designation strip between the
LOW SPEED
slots.
DLP-510
7.
NOTE:
These procedures assume that the DDM-2000 FiberReach
has been connected to the DSX-( ) cross-connect points, as
required.
DS1
,
T1EXT
, and/or
DS3
circuit packs must be
inserted, as required, before performing these tests.
Perform transmission and cross-connect tests for each group, as
required. Refer any failures to organization that installed the
DDM-2000 FiberReach.
DLP-512
8.
NOTE:
A craft interface terminal (CIT) is required to access the
optional features of the DDM-2000 FiberReach. Refer to the
“Commands and Reports” section, and use the rtrv-( )
commands to determine the existing options.
Activate optional features that you require at this time.
9. After each shelf in the network has been tested, the DDM-2000
FiberReach will be ready for end-to-end testing
[
Acceptance: NTP-004
].