363-206-305 Acceptance:
NTP-003
Issue 3, June 2000 Page 3 of 4
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED . . . . FOR DETAILS, GO TO
4.
NOTE:
An inconsistent DCC values alarm will occur when the
OLIUs are looped back. To clear the alarm during a fiber
loopback, use the set-fecom:
address
:com=disable
command to disable the DCC.
DLP-505Install OLIU optical loops between their respective IN and OUT
optical connectors.
5.
!
CAUTION:
The
init-sys:all
command should
NOT
be used on an
in-service system.
NOTE:
A craft interface terminal (CIT) is required to access the
optional features of the DDM-2000 FiberReach.
NOTE:
During installation and/or initial testing, provisionable
parameters may have been set which need to be reset to
their default values. STS1 and/or VT1.5 cross-connections
may have been made which should be deleted before the
system is placed in service. The init-sys:all
command may be used to reset all provisionable parameters
and cross-connections to default values.
NOTE:
An inconsistent DCC values alarm will occur when the
init-sys:all command is executed. To clear the alarm,
use the set-fecom:address:com=disable command to
disable the DCC.
If required, use the command init-sys:all to reset
provisionable parameters to default values.