NTP-003
: Acceptance 363-206-305
Page 2 of 4 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED. . . . .FOR DETAILS, GO TO
NOTE:
The rtrv-( ) commands (rtrv-ne, rtrv-ocl,
rtrv-oc3, rtrv-sync, rtrv-tl, or rtrv-t3) may be
used to retrieve switch settings except for LBO settings on
DS1,
T1EXT
, and
DS3
circuit packs.
Verify correct circuit packs have been installed and option
switches have been set correctly, if not already performed.
DLP-513
2.
NOTE:
If the
ACO/TEST
pushbutton is depressed longer than
2 seconds, the
SYSCTL
display will scroll through the
software version code and all LEDs will remain lit until the
code is displayed.
NOTE:
Software must be installed for this test. If software has not
been installed, the letter
"P"
will be displayed in the
7-segment
FE ID
display. If software has not been installed,
refer problem to the organization that installed the shelf.
Depress and hold the
ACO/TEST
pushbutton on the User Panel.
Verify that all User Panel and circuit pack LEDs and the
SYSCTL
display light. Verify proper version of software is installed.
DLP-509
3. Release the
ACO/TEST
pushbutton. Verify that all LEDs on the
DDM-2000 go off.