363-206-305 Detailed Level Procedure:
DLP-509
Issue 3, June 2000 Page 1 of 2
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
Perform LED Test
1.
!
CAUTION:
Take care to avoid damaging the LEDs that protrude through the
openings in the faceplates of the circuit packs.
Is a CIT available?
If YES, continue with Step 2.
If NO, proceed to Step 5.
2. Connect CIT to User Panel.
Reference: DLP-521
3. Use the test-led:
address
:r=( ) command to test LEDs.
Where address = address identifier of the system, slot, or user panel
that contains the LEDs to be tested. Default is all.
r = number of times (1 through 10) test is repeated.
Response: All LEDs for the specified address identifier light. For a
SYSCTL LED test, all segments of the SYSCTL FE ID
display (including the period) light. After 10 seconds, all
LEDs go off. After another 10 seconds, a completion
message is printed and all LEDs are updated to show the
current status of the system.
4. Did LED test pass?
If YES, STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If NO, proceed to Step 7.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FiberReach DDM-2000 and is the answer not in the manual?

Lucent Technologies FiberReach DDM-2000 Specifications

General IconGeneral
BrandLucent Technologies
ModelFiberReach DDM-2000
CategoryMultiplexer
LanguageEnglish

Related product manuals