NTP-007
: System Turnup 363-206-305
Page 6 of 8 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED. . . . .FOR DETAILS, GO TO
20.
!
CAUTION:
The command
init-sys:all
may affect service. It
should never be used on an in-service system. It should be
used only after a shelf has been equipped to reset all
provisionable parameters and cross-connections to their
default values.
NOTE:
An inconsistent DCC values alarm will occur when the
init-sys:all command is executed because "fecom"
becomes enabled again. To clear the alarm, use the
set-fecom:
address
:com=disable command to disable
the DCC.
Use the init-sys:all command to initialize all provisionable
parameters to their original default values.
21.
NOTE:
A craft interface terminal (CIT) is required to access the
optional features of the DDM-2000 FiberReach, such as
system name, security and logins, date and time, far-end
communications (fecom), etc.
NOTE:
If you choose to make VT1 cross-connections at this time
using the ent-crs-( ) commands, alarm activity will result
when optical fiber loops are removed for end-to-end system
testing.
Activate system features as required from work order or office
records.