363-206-305 System Turnup:
NTP-007
Issue 3, June 2000 Page 5 of 8
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED . . . . .FOR DETAILS, GO TO
14.
NOTE:
This procedure assumes that the DDM-2000 FiberReach
high speed signals are looped back [manual optical (OLIU)
loopback].
DLP-510A. Perform local (looped back) DS1 transmission test.
DLP-545B. Perform local (looped back) DS3 transmission test.
15.
NOTE:
This procedure assumes that the DDM-2000 FiberReach
has been connected to the low-speed DSX cross-connection
as required.
DLP-510A. Perform local wiring DS1 cross-connect test (looped
back).
DLP-545B. Perform local wiring DS3 cross-connect test (looped
back).
DLP-50616. Perform DDM-2000 FiberReach OC-1, OC-3, or OC-12 receiver
sensitivity test (if required). Optional test.
DLP-51617. Check office alarm interface as required.
DLP-51818. Check telemetry interface as required.
DLP-51919. Test protection switching function, if required.