NTP-007
: System Turnup 363-206-305
Page 4 of 8 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED. . . . .FOR DETAILS, GO TO
8. If this is a 1X7 protection configuration, install
177A
Apparatus
Blank cards in any unequipped LOW SPEED slot.
9.
NOTE:
A maximum of three
BBF8 HDSL
circuit packs, including a
protection circuit pack, can be installed in any one LOW
SPEED Group.
DLP-540
Install
BBF8 HDSL
circuit packs (if required).
DLP-546
10. Install
BBG4/BBG4B/BBG19
DS3
circuit packs (if required)
11.
!
CAUTION:
The command
init-sys:all
may affect service. It should
never be used on an in-service system. It should be used
only after a shelf has been equipped to reset all
provisionable parameters and cross-connections to their
default values.
NOTE:
An inconsistent DCC values alarm will occur when the
init-sys:all command is executed because "fecom"
becomes enabled again. To clear the alarm, use the
set-fecom:
address
:com=disable command to disable
the DCC.
Use the init-sys:all command to initialize all provisionable
parameters to their original default values.
12. Use rtrv-eqpt command to verify shelf is equipped for low
speed protection mode required (low-speed protection mode: 1X1
or 1X7).
DLP-509
13. Perform an LED test.